Alpha Black E-Grip problems.
Hello,
I have an Alpha Black with an E-grip. The board will not turn on.
I removed the grips and do not see anything visually wrong with the board or connections. I checked the battery voltage at the battery and it's 8.6v. When I check the battery connections at the board it's around 1.1-1.5v, and the battery gets hot while plugged in. It seems like I am dropping 7-8v through the battery wires. Could the wires inside of the battery side of the connector be shorting somehow? I can't check it without cutting the protective cover.
Has anyone seen anything like this?
Thank You.
__________________
"Only the strong survive. The weak are killed and eaten as fingerfood." SDI SSgt Patterson, USMC Platoon 1077
www.okcpb.net
|