So when I pull the trigger air comes out the solenoid vent instead of actually shooting. What would be the cause of that?
Udfxrookie is offline   Reply With Quote
Old Sponsored Links Remove Advertisement
Advertisement
Old 07-17-2020, 08:08 AM #2
mueller
hypocriticizer
 
mueller's Avatar
 
Join Date: Dec 2014
Location: Chicago west burbs
In order check -
- low battery
- board settings specifically dwell are off
- bolt unable to action (check rings, and bolt should "flick test" smoothly
- insufficient pressure to solenoid (don't crank it either though - too high pressure will break PMR bolts, and noid gaskets) You should be firing at 2.5 to 3 turns out
- mechanical failure at solenoid. Unlikely but happens, not very "checkable"

EDIT: mechanical failure is unlikely on a 2007-2010 rail. 2011+ rail has teh pancake solenoid and mechanical failure is... likely