Find fields & stores near you!
Find fields and stores
Zipcode
PbNation News
PbNation News
Community Focus
Community Focus

ReplyScenario Ups
 
Thread Tools
Old 07-21-2012, 10:58 AM #1
Boom Master
Scenario Player
 
Join Date: May 2009
Location: St. Louis MO, USA, EARTH
Breech Loader from RV Sewer Dump Gate Valve

Finally built one. Now this is for a special R&D project that isn't going so well. The rotating breech made out of a drain leaked a fair amount of air. Thought this would solve my velocity issues but it didn't. The gate valve is air tight though. I used the 3" gate valve for two reasons.

1. All the 2" gate valves were an little undersized. You could Squish a Nerf into it without too much trouble but I couldn't find one that did have clearance. Guys have posted they found one that did but I have been in a dozen RV parts places between Texas, Oklahoma, Arkansas, and MO and haven't found one. So have a nerf with you when you shop for one.

2. My special project required an air chamber all the way around to feed air into the center 2" barrel tube. You don't need that.



You will notice I trimmed the female fittings of both the gate valve and PVC T fitting so the inserted Nerf bulb will be in FRONT of air inlet of the T fitting. Glued but also pinned with some small wood screws just to make sure I don't get a facefull of PVC. With a 2" T fitting, it is quite a bit easier to get the bulb in front of the air inlet.

Open Breech view with a Nerf loaded.



You can see the barrel section extends all the way back to the breech and for my special project FLUSH with the closed gate door. It was relatively easy to ream / trim out the ridge in the 3" x 2" reducer fitting in the front of the T fitting to allow the barrel section to slide through. Used a pocket knife and a band aid.



You can see the air inlet holes into the 2" barrel section. All behind the bulb of the Nerf.

Muzzle view with Nerf Loaded.

You might note the 2" breech barrel section is Schedule 20 Thin Wall PVC. That is part of the special project so use schedule 40 if you want.

This 3" thing is big, bulky, and heavy for a handheld. Below is the mockup using a 2" PVC T fitting on that shower drain. You can easily imagine how much smaller and lighter using a 2" T fitting would be. Use the 2" gate valve and it takes up the same space. If you want the clearance, put the 2" x 3" reducer fitting between the gate valve and the 2" T fitting.



Just so you know, I like detachable, screw on and off barrels. That is why it is so short-some assembly required. Handy for Transport and R & D projects. The 3" Gate valve was $20.

FYI, if you buy those 2" slip x 2" Thread PVC fittings, Take a Nerf with you. Some will pass a Nerf with clearance but other brands will not clear a Nerf. Look for the schedule 20 drain fittings.

Have fun, be safe.
__________________
Carefully planned irresponsibility is the KEY to mental health.

If you haven't grown up by age 50........

You don't have to......

Last edited by Boom Master : 08-04-2012 at 11:54 AM.
Boom Master is offline   Reply With Quote
Old Sponsored Links Remove Advertisement
Advertisement
Old 07-21-2012, 12:18 PM #2
JESTERTLS
 
 
JESTERTLS's Avatar
 
Join Date: Jan 2005
Location: Newton, NC
 has been a member for 10 years
As long as you have the room to open it, it would be an easy way to do a breech.
__________________
JesterTLS "The Great and Powerful."
Team ODX, Detachment 4-Armor
www.cdpaintball.com www.scenariosupply.com www.MilSimEmpire.com
JESTERTLS is offline   Reply With Quote
Old 07-22-2012, 06:50 PM #3
fbkboe
 
 
Join Date: Jan 2009
We've used that set up on our main tank gun and towed AT gun for a couple of years and it works great.
fbkboe is offline   Reply With Quote
Old 07-29-2012, 12:34 PM #4
stevebski
< Kris Williams is HOT
 
stevebski's Avatar
 
Join Date: Aug 2006
Location: MD
 has been a member for 10 years
stevebski supports Bob Gurnsey
stevebski supports our troops
Dale,
I went on their website and saw that they have a flange that is sized the exact same as a 3" pipe, where the flange goes into your 3" Tee. Was that not an option or did you go the route of trimming the female couplings down for another specific reason?
__________________
Kent Island Sea Monkeys - Semper Gumby
PAINTBALL ADVENTURE PARK
stevebski is offline   Reply With Quote
Old 08-04-2012, 11:48 AM #5
Boom Master
Scenario Player
 
Join Date: May 2009
Location: St. Louis MO, USA, EARTH
Yes, I trimmed the coupling down to ensure that the bulb of the Nerf would be in front of the Air Inlet on the 3" T fitting. Not really an issue if you use the 2x1x2 T and use a 2x3" reducer fitting between the T and the gate valve. Still, Take a Nerf with you and measure to make sure that bulb will be in front of the air inlet when loaded.

Don't copy mine literally. Like I said, this is for a special project I am working on. For a standard cannon, use the much lighter and more compact 2x1x2 T fitting,
__________________
Carefully planned irresponsibility is the KEY to mental health.

If you haven't grown up by age 50........

You don't have to......

Last edited by Boom Master : 08-04-2012 at 11:52 AM.
Boom Master is offline   Reply With Quote
ReplyScenario Ups


Thread Tools

Posting Rules
Forum Jump