01-17-2013, 08:46 PM
|
#1
|
|
|
3 way hose
Weres the best place to buy 3 way hose i cant find it on paintballgateway
|
|
|
01-17-2013, 08:50 PM
|
#2
|
|
Join Date: Jul 2007
Location: kansas city
|
|
|
|
01-18-2013, 06:56 AM
|
#4
|
|
|
So i went to my pro shop and got the last hose thy had what can i do to stop the hoses blowing off its the hose that goes to the ram
|
|
|
01-18-2013, 07:37 AM
|
#5
|
|
Join Date: Nov 2003
Location: GA
|
|
|
|
01-18-2013, 09:53 AM
|
#6
|
|
Join Date: Dec 2011
Location: Orcutt, CA
|
Quote:
Originally Posted by whyuuucockin
So i went to my pro shop and got the last hose thy had what can i do to stop the hoses blowing off its the hose that goes to the ram
|
They make tophats for this situation, you sure you got the right size hose? Never had a problem with hoses blowing off except on the DYE 3-ways, they have tiny barbs. Other thing to check is you may have your LPR pressure too high.
|
|
|
01-18-2013, 10:07 AM
|
#7
|
|
|
Ok thanks
|
|
|
01-18-2013, 03:39 PM
|
#8
|
|
|
I second O_nothing
|
|
|
01-18-2013, 06:29 PM
|
#9
|
|
|
Turd my lpr all the way down and tuned it 1/4 turn up and it leaks then i fire and it blows off
|
|
|
01-18-2013, 06:44 PM
|
#10
|
|
Join Date: Dec 2011
Location: Orcutt, CA
|
Quote:
Originally Posted by whyuuucockin
Turd my lpr all the way down and tuned it 1/4 turn up and it leaks then i fire and it blows off
|
Huh?
You have to turn your LPR down, slowly keep turning it up until it starts recocking correctly, then go an extra 1/4 turn from there.
|
|
|
01-18-2013, 07:16 PM
|
#11
|
|
|
I think it needs a rebuild
|
|
|
01-18-2013, 08:17 PM
|
#12
|
|
Join Date: Dec 2011
Location: Orcutt, CA
|
Oh the LPR is blowing off? If so, yes, needs a rebuild
|
|
|
01-18-2013, 08:35 PM
|
#13
|
|
|
No i mean i turn the lpr down and turn it back up just a tad and the frount ram hose blows off the ram sorry from the confusion
|
|
|
01-19-2013, 11:22 AM
|
#14
|
|
SCHWING!
Join Date: May 2004
Location: North County, California
|
Are you tightening the knob down, or loosening it to turn it down?
You should be loosening it. If the hose is popping of, either it's the wrong sized hose, or it's worn out. Clipping off the swollen bit (it should be easy to see) and working the fresh hose onto the barb will get rid of the issue.
|
|
|
01-19-2013, 02:54 PM
|
#15
|
|
|
On a palmers lpr i need to turn to the left
|
|
|
01-19-2013, 05:17 PM
|
#16
|
|
Join Date: Dec 2011
Location: Orcutt, CA
|
Are you sure you got Autococker 3-way hose? 3-way hose is 1/16" ID...... I have a feeling the shop you bought from had hose in stock for the hoppers on the Tippmann's which is 3/32" ID.......
|
|
|
02-28-2013, 06:29 PM
|
#17
|
|
L A S T C A L L
Join Date: Dec 2007
Location: Dallas, GA
|
If you need hose, I sell it for $5 for 3 feet shipped. I only have clear right now, but I am working on getting other colors.
__________________
L A S T C A L L
2011 PSP World Cup Champions
Classic Paintball
|
|
|
03-13-2013, 01:30 AM
|
#18
|
|
|
Might be worth checking your LPR . The piston might be jammed causing it to over pressurize . Hope this helps .
|
|
|
03-16-2013, 03:35 AM
|
#19
|
|
|
One thing I found for popping off hoses, use a on off o ring from an automag on the line.... slide the o ring on the line past where it seats on the barb, put it on the barb then slide the o ring over it... when I had an lpr stick it blew the line up before it popped off the barb.
|
|
|
03-17-2013, 08:11 PM
|
#20
|
|
Join Date: Aug 2012
Location: Port Orchard, WA
|
Quote:
Originally Posted by Cokrkilr
One thing I found for popping off hoses, use a on off o ring from an automag on the line.... slide the o ring on the line past where it seats on the barb, put it on the barb then slide the o ring over it... when I had an lpr stick it blew the line up before it popped off the barb.
|
What size is that o-ring? I've got some 003 3-way o-rings laying around, but they're probably too small.
|
|
|
03-18-2013, 12:23 PM
|
#21
|
|
Don't eat that....
Join Date: Apr 2007
Location: Lynn, AR
|
i second the hose may just be worn and the end just needs to be clipped off, or it just needs replacing. lets face it most cockers are 10+ years old and hoses dont last forever before they dry out and give way.
....or if the gun kicks like a mule..that would be too high on the lpr.
|
|
|