Old Crossfire-Blown Burst Disk?

So, i had my friends old 45-45 crossfire tank re-hyrod after it sat for years. It passed, we filled it up and used it all day problem free. I get home and remove it from the gun, so i fire a few shots and suddenly all the air starts rushing out from what seemed like the burst disk. i was at 3800 PSI and emptied in under 10 seconds. I removed both the burst disks and one of them is blown. Any ideas as to why this would happen, is it something i can just replace and continue use or should i replace the whole reg?
KronicCocker is offline   Reply With Quote
Old 12-16-2012, 08:16 AM #2
Dyoel182
Steel Tank Fan
 
Dyoel182's Avatar
 
Join Date: Jun 2001
Location: North Texas
 has been a member for 10 years
Which one blew?
__________________
2000 Tropic Green CSVT #836/2150
XBL: RapDonkey
Style: Basic Math
Dyoel182 is offline   Reply With Quote
Old 12-16-2012, 08:39 AM #3
Tabris17
Will B/S/T Souls
 
Tabris17's Avatar
 
Join Date: Jan 2006
Location: Connecticut
Annual Supporting Member
Tabris17 is a Moderator
Tabris17 is BST Legit
Tabris17 supports our troops
Tabris17 is one of the top 250 posters on PbNation
Tabris17 is Boss
Tabris17 is attending Decay of Nations VII
It should have been the 1.8k disk. Make sure you get the 7.5k in the correct port, putting it in the LP port creates an extreme safety issue.
You're going to have to send it into crossfire for a rebuild. The older regs aren't meant to be user serviceable and if the burst disc blew then a seal is worn or damaged in the reg and allowing the reg to be exposed to 1.8k psi. That's why it blew.
Tabris17 is offline   Reply With Quote
Old 12-16-2012, 08:42 AM #4
KronicCocker
 
 
KronicCocker's Avatar
 
Join Date: Aug 2002
Location: 508
 has been a member for 10 years
Hmm..neither of these are labeled on the body or the disk as far as a numerical value. Will the new crossfire stealth regs be compatible? If so ill just spend the 30 on a new reg rather than sending this one out.

Correction*** It was the 1.8 not the 7. It is punched in the brass just below the hex head so i didnt see it.

Last edited by KronicCocker : 12-16-2012 at 08:45 AM.
KronicCocker is offline   Reply With Quote
Old 12-16-2012, 08:55 AM #5
Tabris17
Will B/S/T Souls
 
Tabris17's Avatar
 
Join Date: Jan 2006
Location: Connecticut
Annual Supporting Member
Tabris17 is a Moderator
Tabris17 is BST Legit
Tabris17 supports our troops
Tabris17 is one of the top 250 posters on PbNation
Tabris17 is Boss
Tabris17 is attending Decay of Nations VII
The new crossfire regs will fit on the tank and those are user serviceable.
The 7.5k disc should only ever go when the tank is over filled. That's what it's meant for.
Tabris17 is offline   Reply With Quote
Old 12-16-2012, 01:41 PM #6
KronicCocker
 
 
KronicCocker's Avatar
 
Join Date: Aug 2002
Location: 508
 has been a member for 10 years
Thanks much.. Ps I love your Borg!
KronicCocker is offline   Reply With Quote
Old 12-16-2012, 04:53 PM #7
Tabris17
Will B/S/T Souls
 
Tabris17's Avatar
 
Join Date: Jan 2006
Location: Connecticut
Annual Supporting Member
Tabris17 is a Moderator
Tabris17 is BST Legit
Tabris17 supports our troops
Tabris17 is one of the top 250 posters on PbNation
Tabris17 is Boss
Tabris17 is attending Decay of Nations VII
Aww, love is what kills it. It's fueled by hate.
Tabris17 is offline   Reply With Quote
Reply


Thread Tools

Posting Rules
Forum Jump