Old 01-12-2004, 07:51 PM #1
TomServo
 
 
TomServo's Avatar
 
Join Date: Sep 2003
Location: San Diego, CA
Dragun Full Function Problems

Well I was out at the field Sunday and as soon as I screw in my HPA tank the ASA starts leaking air out of the vent hole in the bottom. I thought I killed an o-ring so I replaced it, same thing. Tried another o-ring just to be sure, still venting.

I took a C02 tank one of my buddies had and tried that, still venting. Uh oh, I have no idea why it is doing this. It has been working fine for the past couple months. If I screw the tank in more it just vents more air, lots of air.

I put a bolt o-ring on the tank and it sealed it but it wouldn't allow me to screw the tank into the ASA fully, so my recharge rates sucked all day. any ideas?

I have checked the ASA for any defects and can find none, it is really frustrating.

Actually after thinking about it, I might as well just replace the stock reg, drop and ASA with something new. Any recommendations?, it is still high pressure and I don't know what would be a good reg for it. I would like to get an Drop/ASA with an on/off valve so if anyone has any advice it would really help me out.

Also, is it easy to replace all of the fittings, or should I take it to the shop and get it done?
__________________
  • ICD 2004 Black BKO
  • Dye 12" Ultralight
  • MacDev '04 Gladiator HPR
  • MacDev Sonic LPR
  • MacDev Red Valve

Last edited by TomServo : 01-12-2004 at 07:54 PM.
TomServo is offline  
Old 01-13-2004, 07:53 AM #2
[NA]WARLORD
 
 
[NA]WARLORD's Avatar
 
Join Date: Dec 2001
Location: Sunny FLA !!!!!!!!!!!
[NA]WARLORD is a founding member
 has been a member for 10 years
[NA]WARLORD has achieved Level 1 in PbNation Pursuit
OK, I havent had a stock asa on any of my Dragun's in quite some time, if you look at the face of the ASA, does the thing in the middle appear solid or a screw ? If it's a screw then screw it in 1/4 of a turn incrimants, it sounds like it may have loosened and is depressing the pin valve on your tank prematurely. If it is solid, I have an old school trick to temp fix the problem, just take a bottle oring, drop it in the asa first, before you screw in the bottle, this usually will seal it.

Lastly, judging by your sig, I see you have a PMI tank. Unfortunately, they have one of the worst preset regs on the market. I would take the tank to a proshop and have the valve disassembled and regreased, some shops wont do it, so you may have to take it to a Gas Supply shop.
[NA]WARLORD is offline  
Old 01-13-2004, 08:04 PM #3
TomServo
 
 
TomServo's Avatar
 
Join Date: Sep 2003
Location: San Diego, CA
Thanks for the reply Warlord. The nipple in the ASA is solid and I understand what you are saying, I will try and put an o-ring inside the ASA and see if that works.

It is almost like the o-ring is catching on something and maybe getting pinched inside the ASA. I say this because I cannot fully screw in the tank. Anyway I was thinking about getting a new ASA and drop anyway so I am hoping that will fix my problem. I will let you know if that trick works.

__________________
  • ICD 2004 Black BKO
  • Dye 12" Ultralight
  • MacDev '04 Gladiator HPR
  • MacDev Sonic LPR
  • MacDev Red Valve
TomServo is offline  
Old 01-17-2004, 02:18 PM #4
TomServo
 
 
TomServo's Avatar
 
Join Date: Sep 2003
Location: San Diego, CA
Hey Warlord thanks for the tip. I pulled the tank o-ring off and droped it inside the ASA. It works fine like that but I still don't know why it is leaking when I leave the o-ring on the tank.

At least this will get me through a couple of weekends until I go to the Pomona expo and buy and new reg and drop for my gun.

Thanks for the help again.

-Joe
__________________
  • ICD 2004 Black BKO
  • Dye 12" Ultralight
  • MacDev '04 Gladiator HPR
  • MacDev Sonic LPR
  • MacDev Red Valve
TomServo is offline  
Old 01-17-2004, 05:22 PM #5
[NA]WARLORD
 
 
[NA]WARLORD's Avatar
 
Join Date: Dec 2001
Location: Sunny FLA !!!!!!!!!!!
[NA]WARLORD is a founding member
 has been a member for 10 years
[NA]WARLORD has achieved Level 1 in PbNation Pursuit
I hope you left an oring on the tank too, lol. I meant use an extra oring in the asa.
[NA]WARLORD is offline  
 




Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump

Like us on Facebook Follow us on Google+ Follow us on Twitter Subscribe to us on YouTube
vBulletin Copyright ©2000-2013, Jelsoft Enterprises Ltd and CrowdGather Inc.