Old 03-03-2006, 08:56 PM #64
Eric the Great
not Flavor Flav
 
Eric the Great's Avatar
 
Join Date: Sep 2003
Location: USAs most Dangerous City
Eric the Great is a Supporting Member
id bet 5 year, but its hard to tell w/o a dot#
__________________
TOTAL GREIF
Eric the Great is offline   Reply With Quote
Old 03-07-2006, 05:13 PM #65
acburn22
 
 
Join Date: Oct 2004
Location: Fox Lake
I have a Carleton tank
DOT-E11005
TC-3FCM
6121A-92584 M4927
The date is 04-03
I was wondering when this tank needs to be looked at? Thanks for the help
acburn22 is offline   Reply With Quote
Old 03-07-2006, 06:25 PM #66
Eric the Great
not Flavor Flav
 
Eric the Great's Avatar
 
Join Date: Sep 2003
Location: USAs most Dangerous City
Eric the Great is a Supporting Member
it needs to be hydroed at the end of this month.
__________________
TOTAL GREIF
Eric the Great is offline   Reply With Quote
Old 03-07-2006, 07:40 PM #67
MDcodered91
Rockwood>All
 
MDcodered91's Avatar
 
Join Date: May 2005
Location: Richmond,VA
Is this tank good till 7/07?
MDcodered91 is offline   Reply With Quote
Old 03-07-2006, 07:49 PM #68
Eric the Great
not Flavor Flav
 
Eric the Great's Avatar
 
Join Date: Sep 2003
Location: USAs most Dangerous City
Eric the Great is a Supporting Member
yep it expires the first day of july 07
__________________
TOTAL GREIF
Eric the Great is offline   Reply With Quote
Old 03-20-2006, 01:17 AM #69
Flyboy1986
 
 
Join Date: Feb 2006
Location: Creswell OR
just out of curiosity, I have an SCI tank as well, but it's a Dye throttle and I ve heard two different things from two different techs at my local shop, the DOT information is as follows
DOT-E 10945-4500
ALT 802-4465
05 weird logo thing 03 REE 18.9cc
Do I need to rehydro the tank this year (pretty sure its an 03) or in two years?
__________________
My crappy tripod site
Black ion #113188 Q-lock, 360, Cp long reg, Shocktech trigger, SP Freak Jr., black halo B, 92/45 Throttle con max-flo micro
Tippmann A5 J+J ceramic, GTA double trigger
Spyder Imagine PBGear Expansion Chamber, System x drop rail, SP Progressive, Lapco Feedneck, Dye Stickies, Halo TSA
Flyboy1986 is offline   Reply With Quote
Old 03-20-2006, 01:31 AM #70
p8ntballsteve
Master Airsmith
 
p8ntballsteve's Avatar
 
Join Date: May 2004
Annual Supporting Member
p8ntballsteve is a Supporting Member
p8ntballsteve is playing at Living Legends III
p8ntballsteve is playing at Living Legends V
p8ntballsteve is playing at Living Legends VI
Flyboy1986: Before May 1 2008
__________________
If pitbulls are so dangerous, why did the Little Rascals have one?
A 5 hour class does NOT make you a Tech, Airsmith, Guru, or qualified to do anything but sit in a class for 5 hours
p8ntballsteve is offline   Reply With Quote
Old 03-21-2006, 10:12 PM #71
BlackEagle754
Mr. Slice & Dice
 
BlackEagle754's Avatar
 
Join Date: Aug 2005
Location: Northern NJ
Out of curiosity, is there any difference between a DOT-E number and a DOT-SP number? I just noticed on the DOT list that DOT-E 11005 has been changed to SP-11005. From what I've read, it's just a renewal of the number. I was just wondering if there's any difference between the E and SP.
BlackEagle754 is offline   Reply With Quote
Old 03-21-2006, 11:46 PM #72
phoQ
 
 
Join Date: Mar 2004
DOT-E11194
TC-SU 5303
06 Carleton 02

thanks in advance
phoQ is offline   Reply With Quote
Old 03-23-2006, 06:49 PM #73
BlackEagle754
Mr. Slice & Dice
 
BlackEagle754's Avatar
 
Join Date: Aug 2005
Location: Northern NJ
5 years phoQ.
BlackEagle754 is offline   Reply With Quote
Old 03-25-2006, 12:53 PM #74
jt_gosu
choklat milk pwrs my bonz
 
jt_gosu's Avatar
 
Join Date: Nov 2004
Location: Wyoming
Alright I have a 4oz CO2 tank...on the bottom it says:

DOT-- 3E1800 M9001 10^99 J27

Does it need to be re-hydroed? It's diameter is less than 2"...?
__________________

-'85 Camaro [Being finished...]
-'79 Camaro [Being sold...]
-'72 Dodge Dart [Sold... TT]
-'68 Chevy II Nova [Traded...]
jt_gosu is offline   Reply With Quote
Old 03-25-2006, 06:59 PM #75
Eric the Great
not Flavor Flav
 
Eric the Great's Avatar
 
Join Date: Sep 2003
Location: USAs most Dangerous City
Eric the Great is a Supporting Member
never needs hydro, but the tank is only good for 15 years still.
__________________
TOTAL GREIF
Eric the Great is offline   Reply With Quote
Old 03-25-2006, 10:19 PM #76
jt_gosu
choklat milk pwrs my bonz
 
jt_gosu's Avatar
 
Join Date: Nov 2004
Location: Wyoming
The guy at the shop said it needs hydro...
__________________

-'85 Camaro [Being finished...]
-'79 Camaro [Being sold...]
-'72 Dodge Dart [Sold... TT]
-'68 Chevy II Nova [Traded...]
jt_gosu is offline   Reply With Quote
Old 03-25-2006, 11:51 PM #77
goodlookin1
 
 
goodlookin1's Avatar
 
Join Date: Feb 2006
Hey guys,

Just got a Guerrilla Air Tank today. It is a DOT-E 7277 tank. It is a 68/4500 tank and it's brand new. Hydro date is 05/05.....it's made by SCI (Structural Composites Industries).

Is it 3 or 5 year hydro?

Thanks.
goodlookin1 is offline   Reply With Quote
Old 03-25-2006, 11:59 PM #78
Eric the Great
not Flavor Flav
 
Eric the Great's Avatar
 
Join Date: Sep 2003
Location: USAs most Dangerous City
Eric the Great is a Supporting Member
goodlookin1- 3 year
__________________
TOTAL GREIF
Eric the Great is offline   Reply With Quote
Old 03-26-2006, 12:11 AM #79
Eric the Great
not Flavor Flav
 
Eric the Great's Avatar
 
Join Date: Sep 2003
Location: USAs most Dangerous City
Eric the Great is a Supporting Member
Quote:
Originally Posted by jt_gosu
The guy at the shop said it needs hydro...
print this page and give it to him/her so somebody else dosent have to get turned away w/o a fill.
http://hazmat.dot.gov/sp_app/approvals/regs/180.209.htm

summary:
[Code of Federal Regulations]
[Title 49, Volume 2]
[Revised as of October 1, 2002]
From the U.S. Government Printing Office via GPO Access
[CITE: 49CFR180.209]

[Page 1051-1054]
Table 1.--Requalification of Cylinders \1\
------------------------------------------------------------------------
Specification under which Minimum test
cylinder was made pressure (psig) \2\ Test period (years)
------------------------------------------------------------------------
3E.......................... Test not required...


\1\ Any cylinder not exceeding 2 inches outside diameter and less than 2
feet in length is excepted from volumetric expansion test.
\2\ For cylinders not marked with a service pressure, see Sec.
173.301(e)(1) of this subchapter.
__________________
TOTAL GREIF

Last edited by Eric the Great : 03-26-2006 at 12:14 AM.
Eric the Great is offline   Reply With Quote
Old 03-26-2006, 01:06 PM #80
goodlookin1
 
 
goodlookin1's Avatar
 
Join Date: Feb 2006
Hey Eric The Great,

I went to SCI's website and it said for the paintball tanks that they have 5 year hydro's. Where did you find your info?

http://www.scicomposites.com/paintball_cylinders.html

Thanks,
Ryan
goodlookin1 is offline   Reply With Quote
Old 03-26-2006, 01:16 PM #81
BlackEagle754
Mr. Slice & Dice
 
BlackEagle754's Avatar
 
Join Date: Aug 2005
Location: Northern NJ
Quote:
Originally Posted by goodlookin1
Hey Eric The Great,

I went to SCI's website and it said for the paintball tanks that they have 5 year hydro's. Where did you find your info?

http://www.scicomposites.com/paintball_cylinders.html

Thanks,
Ryan
Their website does not say that their paintball tanks have 5 year hydro test cycles.
It says, "An investment in an SCI carbon composite cylinder represents engineered quality at its best."
Key words there. Carbon composite. You have a FRP (Fiber Reinforced Plastic) tank, AKA Fiberglass. It is a 3 year tank. Just look at the DOT's info on it.
http://hazmat.dot.gov/sp_app/special...000/E07277.pdf
BlackEagle754 is offline   Reply With Quote
Old 03-26-2006, 05:44 PM #82
Eric the Great
not Flavor Flav
 
Eric the Great's Avatar
 
Join Date: Sep 2003
Location: USAs most Dangerous City
Eric the Great is a Supporting Member
my info is straight from the dot, unless i can find it there. then i just make somthing up
__________________
TOTAL GREIF
Eric the Great is offline   Reply With Quote
Old 04-01-2006, 07:04 PM #83
SiLeNt_NiGhT
 
 
SiLeNt_NiGhT's Avatar
 
Join Date: Mar 2006
Location: Eden, Utah
I have a 88/3000 pure energy is it a 3 or 5 year
DOT-E-10915-3000.
last rehydro was 4/02
SiLeNt_NiGhT is offline   Reply With Quote
Old 04-01-2006, 07:55 PM #84
BlackEagle754
Mr. Slice & Dice
 
BlackEagle754's Avatar
 
Join Date: Aug 2005
Location: Northern NJ
5 year tank, Silent.
BlackEagle754 is offline   Reply With Quote
Reply




Thread Tools

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump

Like us on Facebook Follow us on Google+ Follow us on Twitter Subscribe to us on YouTube
vBulletin Copyright ©2000-2013, Jelsoft Enterprises Ltd and CrowdGather Inc.